Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37765818

RESUMO

Traditional Hong-Ou-Mandel (HOM) interferometry, insensitive to photons phase mismatch, proved to be a rugged single-photon interferometric technique. By introducing a post-beam splitter polarization-dependent delay, it is possible to recover phase-sensitive fringes, obtaining a temporal quantum eraser that maintains the ruggedness of the original HOM with enhanced sensitivity. This setup shows promising applications in biological sensing and optical metrology, where high sensitivity requirements are coupled with the necessity to keep light intensity as low as possible to avoid power-induced degradation. In this paper, we developed a highly sensitive single photon birefringence-induced delay sensor operating in the telecom range (1550 nm). By using a temporal quantum eraser based on common path Hongr-Ou-Mandel Interferometry, we were able to achieve a sensitivity of 4 as for an integration time of 2·104 s.

2.
Photoacoustics ; 31: 100518, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37325395

RESUMO

Here we report on a study of the non-radiative relaxation dynamic of 12CH4 and 13CH4 in wet nitrogen-based matrixes by using the quartz-enhanced photoacoustic spectroscopy (QEPAS) technique. The dependence of the QEPAS signal on pressure at fixed matrix composition and on H2O concentration at fixed pressure was investigated. We demonstrated that QEPAS measurements can be used to retrieve both the effective relaxation rate in the matrix, and the V-T relaxation rate associated to collisions with nitrogen and water vapor. No significant differences in measured relaxation rates were observed between the two isotopologues.

3.
Photoacoustics ; 22: 100244, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33604239

RESUMO

We report on a comparison between two optical detection techniques, one based on a Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detection module, where a quartz tuning fork is acoustically coupled with a pair of millimeter-sized resonator tubes; and the other one based on a Photothermal Spectroscopy (PTS) module where a Fabry-Perot interferometer acts as transducer to probe refractive index variations. When resonant optical absorption of modulated light occurs in a gas sample, QEPAS directly detects acoustic waves while PTS probes refractive index variations caused by local heating. Compact QEPAS and PTS detection modules were realized and integrated in a gas sensor system for detection of carbon monoxide (CO), targeting the fundamental band at 4.6 µm by using a distributed-feedback quantum cascade laser. Performance was compared and ultimate detection limits up to ∼ 6 part-per-billion (ppb) and ∼15 ppb were reached for QEPAS and the PTS module, respectively, using 100 s integration time and 40 mW of laser power.

4.
Photoacoustics ; 21: 100227, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33364164

RESUMO

We demonstrated that quartz-enhanced photoacoustic spectroscopy (QEPAS) is an efficient tool to measure the vibrational relaxation rate of gas species, employing quartz tuning forks (QTFs) as sound detectors. Based on the dependence of the QTF resonance frequency on the resonator geometry, a wide range of acoustic frequencies with narrow detection bandwidth was probed. By measuring the QEPAS signal of the target analyte as well as the resonance properties of different QTFs as a function of the gas pressure, the relaxation time can be retrieved. This approach has been tested in the near infrared range by measuring the CH4 (nν4 ) vibrational relaxation rate in a mixture of 1% CH4, 0.15 % H2O in N2, and the H2O (ν1 ) relaxation rate in a mixture of 0.5 % H2O in N2. Relaxation times of 3.2 ms Torr and 0.25 ms Torr were estimated for CH4 and H2O, respectively, in excellent agreement with values reported in literature.

5.
Anal Chem ; 92(20): 13922-13929, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-32962343

RESUMO

An optical sensor for highly sensitive detection of carbon monoxide (CO) in sulfur hexafluoride (SF6) was demonstrated by using the quartz-enhanced photoacoustic spectroscopy technique. A spectrophone composed of a custom 8 kHz T-shaped quartz tuning fork with grooved prongs and a pair of resonator tubes, to amplify the laser-induced acoustic waves, was designed aiming to maximize the CO photoacoustic response in SF6. A theoretical analysis and an experimental investigation of the influence of SF6 gas matrix on spectrophone resonance properties for CO detection have been provided, and the performances were compared with the standard air matrix. A mid-infrared quantum cascade laser with a central wavelength at 4.61 µm, resonant with the fundamental band of CO, and an optical power of 20 mW was employed as the light excitation source. A minimum detection limit of 10 ppb at 10 s of integration time was achieved, and a sensor response time of ∼3 min was measured.

6.
Photoacoustics ; 17: 100155, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31956485

RESUMO

We report on a comparison between piezoelectric and interferometric readouts of vibrations in quartz tuning forks (QTFs) when acting as sound wave transducers in a quartz-enhanced photoacoustic setup (QEPAS) for trace gas detection. A theoretical model relating the prong vibration amplitude with the QTF prong sizes and electrical resistance is proposed. To compare interferometric and piezoelectric readouts, two QTFs have been selected; a tuning fork with rectangular-shape of the prongs, having a resonance frequency of 3.4 kHz and a quality-factor of 4,000, and a QTF with prong having a T-shape characterized by a resonance frequency of 12.4 kHz with a quality-factor of 15,000. Comparison between the interferometric and piezoelectric readouts were performed by using both QTFs in a QEPAS sensor setup for water vapor detection. We demonstrated that the QTF geometry can be properly designed to enhance the signal from a specific readout mode.

7.
Sensors (Basel) ; 19(19)2019 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-31547566

RESUMO

A theoretical model describing the acoustic coupling between two resonator tubes in spectrophones exploiting custom-made quartz tuning forks (QTFs) is proposed. The model is based on an open-end correction to predict the optimal tube length. A calculation of the sound field distribution from one tube exit allowed for the estimation of the optimal radius as a function of the QTF prong spacing and the sound wavelength. The theoretical predictions have been confirmed using experimental studies employing a custom QTF with a fundamental flexural mode resonance frequency of 15.8 kHz and a quality factor of 15,000 at atmospheric pressure. The spacing between the two prongs was 1.5 mm. Spectrophones mounting this QTF were implemented for the quartz-enhanced photoacoustic detection of water vapor in air in the mid-infrared spectral range.

8.
Opt Express ; 27(2): 1401-1415, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30696206

RESUMO

We report on the design, realization, and performance of novel quartz tuning forks (QTFs) optimized for quartz-enhanced photoacoustic spectroscopy (QEPAS). Starting from a QTF geometry designed to provide a fundamental flexural in-plane vibrational mode resonance frequency of ~16 kHz, with a quality factor of 15,000 at atmospheric pressure, two novel geometries have been realized: a QTF with T-shaped prongs and a QTF with prongs having rectangular grooves carved on both surface sides. The QTF with grooves showed the lowest electrical resistance, while the T-shaped prongs QTF provided the best photoacoustic response in terms of signal-to-noise ratio (SNR). When acoustically coupled with a pair of micro-resonator tubes, the T-shaped QTF provides a SNR enhancement of a factor of 60 with respect to the bare QTF, which represents a record value for mid-infrared QEPAS sensing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...